Atola Insight
Atola Insight: Recovering Seagate 7200.11 hard drivesFirst of all, please connect the hard drive's serial port to DiskSense unit by following instructions on the Serial Port Connection page. Open up the Terminal window, select the DiskSense COM port (usually the one that is displayed by default is the correct one). 38400 is the proper speed for 7200.11 hard drives: Once everything is set up, click OK. Make sure that you have attached everything correctly by applying power to the drive (you should see a meaningful output in the terminal window). Note: if you make an error while entering commands, you will get the following message: Invalid Diag Cmd Parameter In this case simply re-enter the command and double-check that you are entering everything exactly as shown in this manual. Once everything is ready and you have powered on the drive, you should see the following (or very similar) output in the terminal window: Rst 0x20M (P) SATA Reset At this point press CTRL+Z. You should receive the command prompt: F3 T> Fixing zero capacity problem1. Type the following: m0,2,2,0,0,0,0,22 and then press ENTER. Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 00, Max Certify Rewrite Retries = 0000 User Partition Format Successful - Elapsed Time 0 mins 00 secs 4. Wait some more time until you see the command prompt again: F3 T> 5. Type the following: /2 and then press ENTER. You will see the following output: F3 T>/2 F3 2> 6. Type capital Z and press ENTER: F3 2>Z Spin Down Complete Elapsed Time 10.543 secs F3 2> 7. At this point you have to re-power the drive. The procedure is complete. Fixing HDD always BUSY problemThis problem is also known as "LED:000000CC problem". This is because when you apply power, you will usually see the following output: Rst 0x10M LED:000000CC FAddr:0025BF67 To fix this issue, please follow these steps: 1. Power off the drive 3. Put a piece of paper as shown on the picture below (the goal is to separate spindle motor contacts from the pcb): 4. If you detached any cables from the drive, this is the right time to attach them back. 5. Apply power to the drive (with screws removed and paper inserted) and wait for the drive to become ready (usually no more than one minute) 6. You will see the following (or very similar) output in the terminal: Rst 0x20M 7. Press CTRL+Z. You will get the command prompt: F3 T> 8. Type the following: /2 and then press ENTER. You will see the following output: F3 T>/2 F3 2> 9. Type capital Z and press ENTER: F3 2>Z Spin Down Complete Elapsed Time 0.132 msecs F3 2> 10. Now remove the paper, put all screws back and tighten them (do not power off the drive!): 11. Type capital U and press ENTER: F3 2>U Spin Up Complete Elapsed Time 6.604 secs F3 2> 12. Type the following: /1 and then press ENTER. You will see the following output: F3 2>/1 F3 1> 13. Type the following: N1 (capital N and one) and then press ENTER. You will see the following output: F3 1>N1 F3 1> 14. Re-power the drive (press Power Off button on the DiskSense unit; wait 10-15 seconds; press Power On button) and wait until it initializes: Rst 0x20M (P) SATA Reset 15. Press CTRL+Z. You will get the command prompt: F3 T> 16. Type the following: i4,1,22 and then press ENTER. You will see the following output: F3 T>i4,1,22 F3 T> 17. At this point do not re-power the drive, scroll to the top of this page and go through Fixing zero capacity problem starting from step 1. |